- Laser methane detector DML-100A
- GNSS (and other allowed) navigation modules
- Thermal imaging module (optional)
- Detection of overheating and cooling of structural elements (optional)
- “Parking” mode to protect optics
- Monitoring of emergency situations and foreign objects
- Visualization of leak locations with data overlay
- Remote detection of natural gas leaks
- Measurement of methane concentration taking into account background values
- GNSS binding of coordinates of detected leaks (and other allowed satellite navigation systems)
Average power consumption............120 W
Optional.................................................up to 56 V
Supply voltage......................................20–42 V
Maximum monitoring height...............150 m
Maximum speed of UAV.....................150 km/h
Continuous operation time..................at least 6 hours
Operating temperature.......................−40°C to +40°C
Data interfaces: Ethernet
Control interfaces: CAN 2.0, RS-232, RS-422, RS-485, Ethernet
Interfaces and compatibility
Ground and air robotic platforms
Measurement error..............................no more than 2 m
Distance measuring range.................20 to 200 m
Wavelength..........................................905 nm
NETD.......................................................≤50 mK
Resolution...............................................at least 640 × 480
Spectral range......................................8–14 µm
Field of view...........................................17° × 14°
Thermal imaging channel (optional)
Weight and dimensions characteristics
Dimensions..........................................Ø290 × 255 mm
Degree of protection........................IP65
Weight.................................................6.5 kg
Resolution...............................................at least 1920 × 1080
Field of view...........................................
Optical zoom........................................1× / 2× / 3×
Frame rate..............................................25 Hz
Methane concentration measurement range: from 50 to 50,000 ppm×m
Response time........................................no more than 0.1 s
Scanning step........................................from 1 to 3 m
Swath width...........................................up to 40 m
- up to 5 min
- up to 11 minutes at temperatures below −20°C
- ≤50 ppm×m at a distance of 50 m
- ≤100 ppm×m at a distance of 100 m
- ≤225 ppm×m at a distance of 150 m
Methane detection distance: from 20 to 150 m